DC motors uses different control technology so it cannot be controlled without additional executive circuit.
Can I control more than one module from my Roller Shutter? Yes you can — use association functionality and control up to 15 roller shutter modules from only one module. How many roller blinds can be controlled by association mechanism? If you use Home Center 2 or Home Center Lite you can associate 15 Roller Shutter modules but it is not recommended to associate more than 10 devices in general.
Can I control and position roller blind of mechanical limit switches? Yes — these roller blinds are fully compatible with our roller shutter module. Can I control and position roller blind with electronic limit switches? You can control such roller blinds but it will not be possible to position them. To control such roller blinds please modify parameter 10 for value 1.
How can I create a scene that will open roller blinds of certain level? Red box is used for defining delay 10 seconds. I have connected Roller Shutter module to my roller blind motor, but it moves only a bit and then stops, why?
Probably you have roller blinds with electronic limit switches, please modify parameter 10 value to 1. When connecting a load to the Plug, make sure it does not exceed 2,W.
Yes, it is available in two versions and designed to be used with E or F type Schuko sockets. The Wall Plug can switch associated devices based on power consumption thresholds. Is it possible to use this to trigger a scene? Yes, Wall Plug can trigger scenes like the switches and dimmers do. Can I perform the inclusion process in one socket and then move the Wall Plug to another location? Would it work properly? Yes, in fact it is recommended to perform inclusion of the device in direct range of the main controller.
Just make sure that final destination is in range of the Home Center controller. Triple click the B button in the final location to adjust the network to the new position. I have a Wall Plug that is working fine but the illumination does not work.
What should I do? Check advanced parameters. You can also activate illumination by pressing and holding the B button until the LED ring starts pulsing white, then releasing the button and pressing it briefly again. If this does not help, try resetting the Wall Plug. How can I check in what way the Wall Plug communicates with the main controller directly or via other devices?
The power data specified by producers are often based on rough estimates or measured in perfect conditions. Real world power depends on mains voltage, device condition or ambient conditions. It is therefore possible for two identical devices to consume different amounts of energy. Why is the power of the same device different depending on the socket it is connected to, in the same house?
Such things happen because of mains voltage fluctuations, wire lengths and voltage drops between the sockets. Why does the power of a device differ at various times of day? The reason is mains voltage fluctuation. Why do we measure power and not other parameters instead? Power measuring is important because it is based on this parameter that electricity suppliers charge households for energy use.
Why does the power of certain devices fluctuate instead of being constant? Some devices may have such characteristics, e. If the connected device frequently and significantly changes power consumption, e. This will reduce Z-Wave network traffic. To reduce the number of power reports, value of the parameters must be modified— by how much will depend on your situation.
The reset will be signaled by double, green, LED ring blink. The LED ring illumination may be turned off completely. After the LED ring has been turned off, it can be turned on again by repeating the above procedure. Can I plug multiple Wall Plugs in the same power strip? Will they interfere with each other when they are close together?
You can connect multiple Wall Plugs in close proximity of each other. They will work properly regardless of that. Can I associate two Wall Plugs? Yes, it is possible by modifying advanced parameters. No, it has been designed to measure energy consumption only. Is it possible to dim connected light sources using the Wall Plug?
This can be used as a bedside lamp. Can I change the frequency that power consumption is reported? Yes, the time interval can be changed in advanced parameters. Remember that it should not be too low. Is the Wall Plug protected from overcurrent or short circuit?
Yes, the Wall Plug automatically recognizes the connected load and is protected from overcurrent or short circuits. The overload safety function allows the controlled device to be turned off if it exceeds a set limit. This is signaled by the LED alternating between yellow and red. Can I turn off the Wall Plug in 'Always on' mode? No, this mode keeps the connected device constantly on and disables reacting to alarm frames and B-button pushes.
Connected device will be turned off only if user-defined overload limit is exceeded. Manuals for firmware Operating manuals for firmware Declarations of conformity: FGR Read this manual before attempting to install the device!
Danger of electrocution! Escape route It is not recommended to operate all of the roller blinds simultaneously. Compatible with any Z-Wave Controller Advanced microprocessor control Executive element — electromagnetic, micro-gap relay switch Works with various types of switches — momentary, toggle and dedicated roller blind switches Active power and energy metering functionality To be installed in wall switch boxes of dimensions allowing for installation, conforming to provisions of applicable regulations This device may be used with all devices certified with Z-Wave certificate and should be compatible with such devices produced by other manufacturers.
When connecting the device act in accordance with the following rules: Connect only in accordance with one of the diagrams Do not connect DC powered motors, Roller Shutter 2 is dedicated to operate AC powered electric motors Do not connect the device to loads exceeding recommended values The device should be installed in a wall switch box compliant with a relevant national safety standards and with depth no less than 60mm Electrical switches used in installation should be compliant with the relevant safety standards Length of wires used to connect the control switch should not exceed 20m.
Venetian blind slats may be only operated by momentary switches. Locate the antenna as far from metal elements as possible connecting wires, bracket rings, etc. Metal surfaces in the direct vicinity of the antenna e.
Do not cut or shorten the antenna — its length is perfectly matched to the band in which the system operates. The device can be added to the network manually or using auto-inclusion function. Removing the device from the Z-Wave network restores all the default parameters of the device.
Quickly, three times press switch no. Place the device within the direct range of your Z-Wave controller Identify switch no. Click Delete to start removing mode. Select More Options three dots icon and click Edit. Select the minus icon - next to the device.
Click Delete to confirm. Choose the device you want to remove and click the arrow next to it. Go to the bottom of the page and click Delete Device. Click Unpair. Click and hold the device you want to remove. Click in the gear icon in the top right corner.
Click Remove device. Confirm that you want to remove this device - click OK. Visual indicator signalling modes: By default, when the device is turned ON, the colour will vary depending on the current active power consumption. Once inserted to mains socket the device signals Z-Wave network inclusion status with blink green — added, red — not added.
Menu position is signalled with assigned illumination colour. Ongoing software update is signalled with cyan blinking. Range of the Z-Wave network with colour depending on type of communication or the lack of it only in range tester mode.
Using momentary switches: Clicking up button connected to the S1 terminal, initiates up movement. Clicking down button connected to the S2 terminal, initiates down movement. Holding up button connected to the S1 terminal initiates slats rotation up.
Holding down button connected to the S2 terminal initiates slats rotation down. Using toggle switches: Changing up button position connected to the S1 terminal, initiates up movement. Changing down button position connected to the S2 terminal, initiates down movement.
Books of special demand are lent out only for shorter period. A reader can take not more than one periodicals at a time. Suggestions shall pertain to technical work of their units. Kitchen Utensil Kenwood KN Marine Radio Kenwood mhz fm transceiver. Meat Grinder Kenwood MG Microcassette Recorder Kenwood DX Mincer Kenwood ATA.
Motorcycle Accessories Kenwood R Musical Table Kenwood kenwood station monitor. Network Card Kenwood DG1. Other kitchen appliances Kenwood AT Oven Kenwood Mini Oven. Personal Computer Kenwood HP Portable CD Player Kenwood Power Supply Kenwood PS Radio Antenna Kenwood AV.
Range Kenwood CK Receiver Kenwood KAC Recording Equipment Kenwood XV Rice Cooker Kenwood FS series. Satellite Radio Kenwood Satellite TV System Kenwood Kenwood Satellite TV System. Saw Kenwood TMA. Scanner Kenwood NX Slow Cooker Kenwood CP
0コメント